用户登录
期刊信息
  • 主管单位:
  • 中国科学技术协会
  • 主办单位:
  • 中国仪器仪表学会、上海光学仪器研究所、中国光学学会工程光学专业委员会
  • 主  编:
  • 庄松林
  • 地  址:
  • 上海市军工路516号上海理工大学《光学仪器》编辑部
  • 邮政编码:
  • 200093
  • 联系电话:
  • 021-55270110
  • 电子邮件:
  • gxyq@usst.edu.cn
  • 国际标准刊号:
  • 1005-5630
  • 国内统一刊号:
  • 31-1504/TH
  • 邮发代号:
  • 单  价:
  • 15.00
  • 定  价:
  • 90.00
双头管封装光纤Bragg光栅低温传感试验研究
Experimental study on the double-head tube packaging fiber Bragg grating at cryogenic temperature
投稿时间:2021-06-02  
DOI:10.3969/j.issn.1005-5630.2022.02.006
中文关键词:  光纤布拉格光栅(FBG)  双头管式  低温传感器  灵敏度  精度
英文关键词:fiber Bragg grating  double-ended tube packaging  low temperature sensor  sensitivity  accuracy
基金项目:载人航天预研项目资助(18100040401)
作者单位E-mail
杨才千 东南大学 土木工程学院,江苏 南京 210096
湘潭大学 土木工程与力学学院,湖南 湘潭 411105 
 
文峰 湘潭大学 土木工程与力学学院,湖南 湘潭 411105 文峰(1996-),男,硕士研究生,研究方向为光纤传感及结构监测研究。E-mail;1825747142@qq.com 
周正 湘潭大学 土木工程与力学学院,湖南 湘潭 411105  
杨宁 山东航天电子技术研究所,山东 烟台 264670  
姚远 湘潭大学 土木工程与力学学院,湖南 湘潭 411105  
李帅 湘潭大学 土木工程与力学学院,湖南 湘潭 411105  
摘要点击次数: 2485
全文下载次数: 1770
中文摘要:
      提出并设计了一种用于低温环境下测量温度的光纤布拉格光栅(FBG)双头管式封装结构,探究了涂覆层材料和封装形式对光纤Bragg光栅传感器低温传感稳定性和精度的影响。同时,试验研究了封装长度对双头管式传感器中心波长与温度的关系,通过多次重复试验测定了传感器低温灵敏度和重复性误差。研究结果表明:由于高折丙烯酸酯涂覆层具有较高的热膨胀系数,因此在77~273 K液氮环境中其增敏效果相对于聚酰亚胺和裸光纤更为显著;采用双头管封装后,FBG中心波长与温度具有高度线性关系,且能有效解决无封装裸FBG易受荷载扰动特性;适当提高封装长度有利于提高封装体系灵敏度系数。重复试验结果表明,所设计的双头管式封装FBG低温传感器灵敏度可达14~20 pm/K,测试误差和灵敏度优于传统FBG低温传感器。
英文摘要:
      A cryogenic temperature sensor with FBG double-head tube package form was designed and studied in the current study. The effects of coating materials and packaging forms on the stability and accuracy of the proposed fiber Bragg grating at cryogenic temperature were experimentally investigated. The effects of packaging length and correlations between central wavelength and temperature were further revealed. The sensitivity and repeatability error of cryogenic temperature sensors were calibrated through a series of repeated tests. The experimental results demonstrated that owing to the relatively higher thermal expansion coefficient, the high refractive acrylic coating FBG presented better sensitization properties than the Polyimide and bare optical fiber in liquid Nitrogen environments(77~273 K). The central wavelength displayed promising linear correlations with environmental temperature with double-head tube packaging, which could also mitigate the vibration-induced disturbance. In addition, the increase in package length is beneficial in enhancing the sensitivity of FBG sensors. The sensitivity of designed low temperature sensor can reach up to 14~20 pm/K, which is superior to traditional FBG sensors.
HTML   查看全文  查看/发表评论  下载PDF阅读器
关闭