| 中文摘要: |
| 根据交流发光二极管(AC-LED)的工作特征,提出了一种简单而精准的AC-LED结温测量方法:开启电压法。通过理论分析和实验发现,AC-LED的开启电压会随着结温的上升而下降,且两者之间有良好的线性关系,从而确认将开启电压作为温度变化参数来间接测量AC-LED的结温。实验表明,开启电压法测量结温的重复性最大误差为2.0 ℃,热阻重复性最大误差为0.6 ℃/W。经过对比分析,开启电压法得到热阻值比参考脉冲法更接近真实值。 |
| 英文摘要: |
| At present, the measurement methods of LED junction temperature are mainly aiming at direct current LED(DC-LED), and less methods have been proposed for alter current LED(AC-LED). With regard to this fact, a novel cut-in voltage method was proposed for measuring AC-LED junction temperature. From theoretical analysis and experimental verification, cut-in voltage of AC-LED was found to decrease along with the increase of junction temperature, demonstrating a good linear relationship between the two factors. Therefore, cut-in voltage was confirmed as the temperature variation coefficient(TVC). Further analysis suggested that the repeatability error of junction temperature and thermal resistance could be narrowed down to 2.0 ℃ and 0.6 ℃/W respectively. By comparison, thermal resistance acquired from cut-in voltage method was closer to real value than that of the reference pulse method. |