| 对人工晶体分辨力标准的探讨 |
| A discussion about the resolving power of IOL |
| |
| DOI: |
| 中文关键词: 白内障,人工晶体,分辨力,有效分辨率,大度数 |
| 英文关键词:cataract,intraocular lens,resolving power,resolution efficiency,larger power. |
| 基金项目: |
| 吴叶华 |
| 上海光学仪器研究所,上海,200093 |
| 摘要点击次数: 3529 |
| 全文下载次数: 18 |
| 中文摘要: |
| 分析了人工晶体分辨力和评定标准的来源.由于人工晶体的生产引进国内才5年,对大度数人工晶体来说,现行的行业标准规定的分辨力为60%以上是不合理的,55%以上作为标准是可行的. |
| 英文摘要: |
| ]This paper analyzed the resolving power of IOL and the source of criteria.It is only 5 years that manufacturing technology for IOL introduced into China.For larger power,the resolving power is 60% for all powers in the current industrial standard,but we think it is not suitable and 55% is acceptable for larger power of IOL. |